Knowledge article
TroubleshootingIntermediateR-20, R-50, C-10, S-5
Troubleshooting E-8041 Faults: Realigning Light Curtains on the NXB-MNT-612-010 Mount Set

This procedure should only be performed by qualified maintenance personnel. ... Inspect the Mount: Visually inspect the NXB-MNT-612-010 mount sets on both the ... Securely fasten all hardware.

Knowledge article
TroubleshootingIntermediateR-20, R-100, C-10, S-5
Troubleshooting E-8014 Encoder Communication Fault After Servo Replacement (NXB-TRN-911-011)

Confirm that it is secured with the appropriate cable clamps and maintains the ... Navigate to the [SYSTEM] > [MASTER/CAL] screen on the teach pendant. ... Step 5: Verification

Knowledge article
Maintenance GuideIntermediateR-20, R-50, C-10
Scheduled Maintenance for the NexBot Drives 421-006 Automatic Tool Changer

Isopropyl alcohol (99%) ... Ensure the robot and all related equipment are de-energized and cannot move ... The attached end-of-arm tool must be safely supported or removed. Preparation:

Knowledge article
TroubleshootingIntermediateR-20, C-10, S-5
Troubleshooting PF-003: Ingress Detected at Cable Entry Point due to Grommet Failure (NXB-GEN-543-004)

Carefully disconnect the conductors. Remove Old Grommet: From inside the enclosure, carefully push the center of the ... Install New Grommet: Confirm the replacement part is a genuine

Knowledge article
Maintenance GuideAdvancedR-20, R-50, C-10, S-5
Scheduled Maintenance for the NexBot Drives 642-006 Robot Mount

Article ... Ensure the work area is clear of obstacles. ... Cracks in the paint or base metal ... Elongated or damaged bolt holes Inspect all weld seams for signs of cracking or fatigue.

Knowledge article
How-ToIntermediateR-20, R-50, R-100
How to Install the NXB-CBL-541-009 Cable Carrier on NexBot R-Series Robots

Ensure the following: ... Do not overfill the carrier. ... Step 6: Secure Carrier and Cables With the carrier brackets loosely mounted and cables routed, manually articulate the robot ...

Knowledge article
TroubleshootingIntermediateR-20, R-100, C-10, S-5
Troubleshooting E-8021 (Safety Input Fault) from Light Curtain Misalignment on NXB-MNT-612-009 Mounts

Place the laser on one unit and target the other to check for parallel and co-linear alignment ... M8 Frame Mounting Bolts: Tighten the bolts securing the mount base to the safety ... Keywords

Knowledge article
Technical NoteIntermediateR-10, R-20, C-5
Technical Bulletin: Utilizing the NXB-KIT-761-002 Kit for 4,000-Hour Scheduled Maintenance

Hex key set ... Install the new Control Cabinet Desiccant Pack from the NXB-KIT-761-002 into the ... Remove the two old filter elements. Clean the filter bowl with a lint-free wipe.

Document
datasheetpdfNXB-GEN-833-013
NexBot Robotics 833-013 Washer And Spacer Set (Stainless Steel) — Technical Datasheet

Technical Specifications ... Material ... Country of Origin JP ... © 2026 NexBot Robotics. All specifications subject to change without notice. Document ID: DS-NXB-GEN-833-013-1.0

Document
user_manualpdfNXB-GEN-221-019
NexBot Robotics 221-019 Teach Pendant with 10.1-inch Display — User Manual

All programming and manual movements must be performed in T1 or T2 mode. ... Manual Robot Jogging ... Tip: For precise positioning, use Joint mode to move individual robot axes. ... Task

Document
installation_guidepdfNXB-GEN-VAC413-016
NexBot Robotics VAC413-016 Vacuum Gripper 16 kg Lift Capacity — Installation Guide

Tighten the bolts in a star or cross pattern to the specified torque of 16 Nm using a ... In the robot controller software, define the gripper's TCP based on its dimensions (180 x 150 x 120 mm ...

Document
installation_guidepdfNXB-GEN-242-018
NexBot Drives 242-018 Analog I/O Module — Installation Guide

Step 4: Connect System Ground ... Ensure a low-impedance connection for proper noise immunity and safety. ... Ensure the connector is fully seated to establish a reliable data link.